Model | V-max (Vdc) | I-max (A) | I-hold (A) | I-trip (A) | Agency Approval |
SMD0603-010 | 15V | 40A | 0.10A | 0.30A | RoHS |
SMD0603-020 | 9V | 40A | 0.20A | 0.50A | RoHS |
SMD0603-025 | 9V | 40A | 0.25A | 0.55A | RoHS |
SMD0603-035 | 6V | 40A | 0.35A | 0.75A | RoHS |
SMD0603-050 | 6V | 40A | 0.50A | 1.00A | RoHS |
SMD0603-075 | 6V | 40A | 0.75A | 1.40A | RoHS |
SMD0603-100 | 6V | 40A | 1.00A | 2.00A | RoHS |
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25℃ still air.
ItRip = Trip Current:minimum current at which the device will trip in 25℃ still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).