Model | V-max (Vdc) | I-max (A) | I-hold (A) | I-trip (A) | Agency Approval |
SMD0805-010 | 15 | 100 | 0.10 | 0.30 | RoHS |
SMD0805-020 | 9 | 100 | 0.20 | 0.50 | UL/RoHS |
SMD0805-035 | 6 | 100 | 0.35 | 0.75 | UL/RoHS |
SMD0805-050 | 6 | 100 | 0.50 | 1.00 | UL/RoHS |
SMD0805-075 | 6 | 40 | 0.75 | 1.50 | UL/RoHS |
SMD0805-100 | 6 | 100 | 1.00 | 1.95 | UL/TUV/RoHS |
SMD0805-110 | 6 | 100 | 1.10 | 2.20 | UL/RoHS |
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25℃ still air.
ItRip = Trip Current:minimum current at which the device will trip in 25℃ still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).