Model | V-max (Vdc) | I-max (A) | I-hold (A) | I-trip (A) | Agency Approval |
mSMD010 | 30 | 100 | 0.1 | 0.3 | RoHS |
mSMD014 | 60 | 100 | 0.14 | 0.34 | RoHS |
mSMD020 | 30 | 100 | 0.2 | 0.4 | RoHS |
mSMD050 | 15 | 100 | 0.5 | 1 | UL/RoHS |
mSMD075 | 13.2 | 40 | 0.75 | 1.5 | UL/RoHS |
mSMD075-16V | 16 | 100 | 0.75 | 1.5 | RoHS |
mSMD110 | 8 | 100 | 1.1 | 2.2 | UL/RoHS |
mSMD110-16V | 16 | 100 | 1.1 | 2.2 | RoHS |
mSMD125 | 16 | 100 | 1.25 | 2.5 | RoHS |
mSMD150 | 8 | 100 | 1.5 | 3 | UL/RoHS |
mSMD150-12V | 12 | 100 | 1.5 | 3 | RoHS |
mSMD150-16V | 16 | 100 | 1.5 | 3 | RoHS |
mSMD160 | 8 | 100 | 1.6 | 2.8 | UL/RoHS |
mSMD200 | 8 | 100 | 2 | 4 | UL/RoHS |
mSMD260 | 8 | 100 | 2.6 | 5 | RoHS |
Ihold = Hold Current:maximum current device will sustain for 4 hours without tripping in 25℃ still air.
ItRip = Trip Current:minimum current at which the device will trip in 25℃ still air.
V-max = Maximum voltage device can withstand without damage at rated current(I-max).
I-max = Maximum fault current device can withstand without damage at rated voltage(V-max).