Operation Pressure: 80 ~ 100 PSI ; "*" REMARKS FOR 150 ~ 220 PSI.
Rejection : 90 ~ 97%
Recovery Rate: 15 ~ 50%
Feedwater Conditions
Inlet Pressure ------------- >1.5 kg/cm2 Chloring ------------- < 0.1 ppm
Total Hardness ----------- <10 ppm as CaCO3 Turbidity ------------ < 2 NTU
Fe ----------------------------- < 0.1 ppm SDI ------------------- < 4
Features
a. Low-pressure protection switch.
b. Product Hi-level control.
c. Concentrate recycle-flow regulator.
d. Digital feed / product water quality meter.
e. Automatic power shut-off device if pre-treatment system is in regeneration process.
f. Optional automatically operates and IC control device.
g. Optional automatic flush device.
h. Operating pressure set-up device.
i. Optional #SUS 304 made skids.
j. Optional over-heat protection device for pump.
promotional Packages(RO-50A-YT RO-50N-YT)