Details
Functions :
1. Security and convenience:
The lamps always light when people arrived
2. Energy saving:
Lamps will be off after people left.
Characteristics :
1. D.I.Y. design:
Easy for everyone to install and use.
2. Free lamps use:
All type of brand or lamp can be installed and detected ON/OFF.
3. Free adjustment:
Detective direction and angle can be free screw around
355° degree.
4. The smallest size:
Only 1/3 cubical size of similar item, but sensitivity are twice of other similar one.
5. All direction installation:
No matter lamp upward, down word or outside ward, all can be installed easily by anyone.
6. No light feed back:
Use the technology of 3 patents to overcome the light feed back problems.

Application area:
Hallway, door gate, corridor, stairs, garage, balcony and basement. etc.
Attentions:
Prevent humidity, prevent wrong voltage.

Model Specification: PIR-505 All Direction Screw-in Light Sensor
Power Supply: AC110V / 220V  50HZ~60HZ
Load: Tungsten lamp 60W Provincial Electric: 23W
Fluorescent lamp:23W
Power Consumption: 13mA
Sensing Angle: Rotation range about 355 degree < 170 degree
Sensing Distance: 25°C < Within 8 meters
Off Delay time Day : 5sec
Night : 60sec
Night : 300sec
Illumination: Under 8LUX
Preparation Time: After light brighting for 15~300 sec. When been electrified.
Dimension 6 x 6 x 6.5CM
Weight: 70g
Wiring: Screw-in Pin
Temperature: Difference Between 2 Points Above >3°C
Operating Temperature: -5°C~45°C,23°F~113°F
Relative humidity: Under 90%
Installation Location: Any location with screw-in socket of E26 E27.
Notes:
1.Should avoid sunshine vent of air vent and other draft even installation location.
2.Avoid humidity.
3.Lamps not being bright lights but LED bright lights, please replacement the lamp.