Features:
*With More Effective Media Area
*With High Capacity
*With Low Resistance
*With High Dust Collection Capacity
*With Longer Life Span

AIRREX V-Cell Air Filter is with multiple mini-pleat media packs and enable to remove air contamination, such as dust, smoke, vapor, soot, pollen, bacteria and etc. The unique V-Type design offers a wide range of efficiency to remove air contamination and provide a very low resistance. V-Cell filter offers high performance and low operating costs; it is ideal for the most difficult operating conditions:

*High Velocity
*Variable Air Volume System
*High Humidity
*Corrosion Environment

AIRREX V-Cell Air Filter is assembled by eight pieces of mini-pleat packs to compose of four (4) V Types. It contains more media (up to 40%) than standard W-Cell Air Filters. The effective media area results in greater flow capacity, lower resistance, higher dust collection capacity and longer life span. Operating range of Face Velocity is from
0 to 750FPM (0-3.81M/sec) for 12''(292mm) deep units.

Efficiency:
Per ASHRAE 52.1-1992 standard, the filters have an average atmospheric dust spot efficiency range 60-65%, 80-85% and 90-95% (in NBS Test Method); per ASHRAE 52.2, the efficiency is MERV11, MERV12 & MERV14.

Media:
V-Cell media is manufactured from water-resistant glass microfiber. The media is pleated from the filter pack and use hot melting glue to replac the traditional aluminum separators.
V-Cell media can withstand temperature up to 350°C. The connection between filter face and frame is sealed by fire retardant epoxy, polyurethane foam or silicon to ensure the filter leakage free.

Outer frame:
The frame is available for metal frame (Galvanized Steel, Aluminum and Stainless Steel) in box type or header type and ABS frame in headed type.

V-Cell Air Filter Operating Conditions:
*Recommended Final Pressure Drop: 2.0''w.g.
*Maximum Final Pressure Drop: 3.2''w.g.
*Guaranteed to withstand burst pressure: 6.0''w.g.
*Actual Average Burst Pressure: 10.0'' w.g.
*Relative Humidity: 100%